温控阀导致的压缩机联锁停车故障分析
雷鸣
(中沙(天津)石化有限公司,天津 300271)
摘要:某LLDPE装置的两台往复式氮气压缩机,在春季试车后运行一直正常,但是进入夏季后,频繁出现润滑油压力报警,导致压缩机联锁停车的事故。通过分析,得出了温控阀非正常动作是造成润滑油供油压力报警和联锁机组停车的原因,最终发现温控阀的冷热油管路误接,并解决了问题。
关键词:温控阀;温度;压力;压缩机
中图分类号:TH45 文献标志码:B doi:10.3969/j.issn.1006-0316.2015.03.020
文章编号:1006-0316 (2015) 03-0077-04
Failure analysis of interlock and shutdown of compressor caused by temperature control valve 
LEI Ming
( SINOPEC & SABIC Tianjin Petrochemical Co., Ltd., Tianjin 300271, China )
Abstract:The two reciprocating nitrogen-gas compressors of LLDPE plant work normally after test run in the spring. But in the summer, the oil pressure alarm is activated frequently, which cause the compressor stop with interlock. Through the analysis, we find out the reason that the abnormal movements of temperature control valve causes the alarm of oil pressure and interlock the compressor stopping. Finally, we found the pipeline misconnection of hot oil and cold oil of temperature control valve, and solve the problem at last.
Key words:temperature control valve;temperature;pressure;compressor
———————————————
收稿日期:2014-03-20
作者简介:雷鸣(1982-),男,河北秦皇岛人,本科,工程师,主要从事设备维修管理工作。
 

 