空分装置冷箱内泄漏的分析
黄凤英
(四川空分设备(集团)有限责任公司,四川 简阳 641400)
摘要:空分装置冷箱内泄漏后,对相关运行数据进行了分析,主要有主塔基础温度、冷箱夹层中多个取样点含氧量、每日总液体产量,比较装置重启运前后、密封气流量大小变化前后、不同膨胀机运行时对其影响,分析推断出了泄漏介质、介质状态、漏点大致位置,估算出了每日漏量。由此,企业做出了加强对冷箱的安全监管、维持此状态继续运行的决定。一年半后对装置进行了成功检修,发现实际泄漏点情况与分析推断的结论基本吻合。
关键词:空分装置;内泄漏;分析推断
中图分类号:TQ051.8           文献标识码:B         文章编号:1006-0316 (2013) 05-0077-04
Analysis for internal leakage of cold box of air separation plant
HUANG Feng-ying 
( Sichuan Air Separation Plant(Group)Co.,Ltd., Jianyang 641400, China )
Abstracts:This paper analyzed the relevant running data of the plant for the internal leakage of the cold box of air separation plant, including the temperature of the main column foundation, the oxygen content at several sampling points inside the cold box and the total daily liquid output, compared the leakage before & after restarting of the plant and that before & after changing of the sealing gas flow and the influence on the leakage by different expanders. The paper also analyzed and deduced the leaked medium, the medium state and the possible leaking location and estimated the daily leakage. On this basis, the company decided to strengthen the safety monitoring to the cold box and to keep the plant running at this state. After one and half years, the plant was maintained successful and showed that actual leakage was the same as the conclusion of the above analysis.
Key words:air separation plant;internal leakage;analysis and deduction

———————————————
收稿日期:2012-10-15 
作者简介:黄凤英(1972-),重庆人,工程硕士,工程师,主要从事过活塞式压缩机设计、空分装置单体设备设计及空分装置运行技术研究等工作。
 

 

设为首页  |  加入收藏    |   免责条款
《机械》杂志版权所有     Copyright©2008-2012 Jixiezazhi.com All Rights Reserved 

  电话:028-85925070    传真:028-85925073    E-mail:jixie@vip.163.com

地址:四川省成都锦江工业开发区墨香路48号   邮编:610063

蜀ICP备08103512号

Powered by PageAdmin CMS